<h1>Sunshine sensors load cell manufacturer india offer load cell, load cells, precision load cell, single point load cell, single point platform load cell, single point table top load cell, single point miniature load cell, miniature load cell, s beam load cell, beam load cell, double ended shear beam load cell, shear beam load cell,digital load cell, jewellery Load cell, load cell calibration,Compression Load Cell</h1>
Home | Sitemap | E-mail us
 
Single point platform load cell Digital Load Cell NEW
Single point platform load cell Single Point Platform
Load Cell
Single point table top load cell Single Point Table Top
Load Cell
Single point miniature load cell Single Point Miniature
Load Cell
S beam load cell S Beam
Load Cell
Double ended shear beam load cell Double Ended Shear
Beam Load Cell
Double ended shear beam load cell Single Ended Beam
Load Cell
Double ended shear beam load cell Compression Load Cell
 
 
Compression Load Cell
Compression Load Cell Model RC3
Model Information  |  Dimension  |  Photograph
 
Model Information :
Double ended shear beam load cell, shear beam load cell, load cell manufacturer India

Flintec  load  cells are designed to meet the most stringent accurcy requirements.

Certificaties have been obtained from Weights & measures Authorities. Worldwide.

RC3 rocker coumn load cell are available in the capacities 7.5 t to 300 t and include Accuracy classifications GP,C 1, C3, C4, and C3 MI 8according to OIML R 60: NTEP n max =10000

They offer total stainless ateel construction and complete hermetic sealic sealing, MAKING them suitable for use in the toughest industrial environments.

This load cell design in combination with a low cost self aligning rocker assembly, unites excellent load introduction eith a low profile outline.

The Flintec calibration  technique (in m V / V /Q) eliminates time consuming comer calibration in multiple load systems.

The RC3 is available for use in hazardous areas Zone 0. 1. 2. (gas) and 20. 21. 22 (dust) according to EEx ia IIC T6......T4 T130 0C ATEX.

IMPORTANT FEATURES

o Capacities : 7.5t to 50 t
o High accuracy.
o Total stainless steel construction.
o Complete hermetic sealing.
o Protection IP 68
o High input resistance : 1100 Ω.
o W&M certified for 4000 intervals. (PTB : D09-99.09 Rev.2)
o Calibration in mV/V/Ω.
o Easy cable replacement.
o Complete range of loading hardware available.
o Factory Mutual approved.

Options

o
Explosion protection zone 0,1,2 and 20,21,22 ATEX.
o Integrated surge arrestors (4x)

RC3 Specifications ::
Maximum Capacity (Emax) t
7.5/15/22.5
30/40/50
100/150/300
7.5/15/22.5/30/40/50
Rated Output (Cn) mV/V 2±0.1%
Calibration in mV/V/Ω (A...I classified) %Cn <±0.05(<±0.005)
Accuracy class according to OIML R 60
Maximum number of vertification intervals (nmax)
Minimum load cell vertification interval (Vmin)
Combined error
Creep error (30 minutes) / DR
Temperature effect on minimum dead load output
Temperature effect on sensitivity
 
 
%Cn
%Cn
%Cn/°C
%/°C
(GP) C1 C3 C4 C3 MI 8
n.a. 1000 3000 4000 3000
n.a. Emax/5000 Emax/15000
0.040 0.030 0.020 0.018 0.015
0.060 0.049 0.016 0.012 0.006
0.0040 0.0028 0.0009 0.0009 0.0009
0.0020 0.0015 0.0010 0.0008 0.0010
Excitation Voltage V 5...15
Zero balance %Cn 5
Input resistance Ω 1120±50
Output resistance Ω 1000±2
Insulation resistance (100 DC) >5000
Compensated temperature range °C -10...+40
Operating temperature range °C -40...+80
Safe load limit (Elim) %Emax 200
Ultimate load %Emax 300
Load cell material   stainless steel 17-4 PH (1.4548)
Sealing   Complete hermetic Sealing cable entry sealed by glass to metal header
Protection according DIN 40.050   IP68
     
 
*The data for deviation of linearity, repeatability, hysteresis error and temperature effect on sensitivity are typical values. The sum of these data meets the requirements according to OIML R60.

 

 